Tianxing Cable Good Core Manufacturing
Sales hotline +86 16678668098

Hot search keywords : Control cableSoft sheathed cableComputer cableRS485 cable

Your location : Home > Low-voltage cable >

YJLV VLV aluminum cable

Executive standard: GB/T12706.1-2020 Product specifications: 1.5mm2-300mm2 (1 core, 2 cores, 3 cores, 4 cores, 5 cores, 4+1 cores, 3+2 cores, 3+1 cores)

Want to know about this product?

Contact Tianxing Cable

+86 16678668098

Product introduction
Characteristics of YJLV cable: The maximum rated working temperature of the conductor of the cable is 90 ℃, and the maximum working temperature is less than or equal to+70 ℃. The cable temperature should not exceed 160 ℃ within a 5-second short circuit time, and the ambient temperature during laying should not be lower than 0 ℃.
YJLV cables can be laid indoors, in trenches and pipelines, or buried in loose, insulated PVC sheathed power cable soil, and cannot withstand external forces. When YJLV cables are laid underground, they can withstand mechanical external forces but cannot withstand large tensile forces.
PVC insulated power cables have good electrical performance and chemical stability. Simple in structure and convenient to use, suitable for fixed installation on transmission and distribution lines with AC 50Hz and rated voltage of 1kV and below. Among them, the five core power cable is designed to adapt to the development and safety performance needs of the distribution system. It separates the neutral and neutral lines in low-voltage distribution system engineering, making the system operation more stable and ensuring the safety of workers.

Usage characteristics
01. The long-term working temperature of the cable conductor shall not exceed 70 ℃, and the working temperature of the cable conductor during short circuit shall not exceed 160 ℃ (for 5 seconds);
02. When laying cables, the small bending radius (D is the outer diameter of the cable) is 20D for single core unarmored cables, 15D for multi-core unarmored cables, 15D for single core armored cables, and 12D for multi-core armored cables. The ambient temperature for cable laying should not be lower than 0 ℃.

Hot product

Refractory wire /NH series

Refractory wire refers to the cable that can maintain a certain period of safe operation in the case of flame combustion. Fire-resistant cables are widely used in high-rise buildings, underground railways, underground streets, large power stations and important industrial and mining enterprises and other places related to fire safety and fire rescue, such as fire equipment and emergency lighting and other emergency facilities power supply lines and control lines.

Long life wire

Hotline number

+86 16678668098